Specifications

-------------------
Worked hours
Hours under power
State good
At local norms ---------
Status visible

Description

USED SUPERCRITICAL CO2 EXTRACTOR
Model: EXTRAKTLAB 140
Refurbished in 2021 (to brand new equivalent condition)

Processes up to 8 kg of input material per hour depending on process conditions.
Extraction vessels: 2 x 20 L
Collection vessels: 3 x 2,5 L
Recycler vessels: 1 x 20 L
CO2 Pump Flow Rates Range (LPM): 1.5 to 2 LPM
Max Operating Pressure (psi): 5000 psi, 344.74 bar
Maximum Process Temperature: 90°C
Skid Operating Temperature (C°): 5 to 40°C (15 to 30°C optimal)
CO2 Solvent Inlet Lines: 1
Eluent Inlet Lines: up to 2
User Interface: Touch Screen HMI panel with barcode scanner, maintenance tracking, recipe storage (parameter). 21 CFR Part 11 compliant software.
Biomass Loading and Unloading: 10 micron flexible no channel bags
Operating Humidity: 20 to 80%
Compliance - UL 508A electrical panel Electrical - 50 Hz 208V-240V, 3 phase,
Footprint:- 24ft. Dimensions - 99" x 34" x 72" (LxWxH)
Construction: 316 stainless steel, Ferrule compression fittingsthroughout
Sound Pressure - 50 dB
Wetted Materials - FDA approved structural stainless steel.
Chemical Compatibility: CO2, Organic Solvents, Acids and Bases, plant extracts
Flow Control: Manual, Automatic
Flowe Meter: PID Controlled Algorithm, rules based onprocess parameters
CE and food grade GMP certified
Independently P.E. Stamped according to ASME DIV II VII-2PED compliant, CE marked, notified body, Lloyd’s Register, CRN number available
Safety Specifications:
Rupture Discs: Zook burst discs, calibrated, ASME VIII Div IIcompliant, Max Pressure is 5300 psi, Certificate Attached to Disc
Temperature Switch: Preheater, Post heater MAX TEMP 140°C,Certificate Available Collector, Extractors MAX TEMP 100°C, Certificate Available
E-stop Switch: Switch disengages main contactor, not dependenton PLC
CO2 Gas Detector: Built in alarm, turns off pump and closes valves at9000
Interlocks: Marked with safety warnings
Pressure Transducers: Post pump, Extractor, Collector 1,3; Turns off pumpwhen overpressure (>5100 psi) condition is detected
Isolation Valves: Manual, bypass valves.
Technical documentation: available.

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Client type Reseller
Active since 2023
Offers online 13
Last activity Dec. 24, 2024

Description

USED SUPERCRITICAL CO2 EXTRACTOR
Model: EXTRAKTLAB 140
Refurbished in 2021 (to brand new equivalent condition)

Processes up to 8 kg of input material per hour depending on process conditions.
Extraction vessels: 2 x 20 L
Collection vessels: 3 x 2,5 L
Recycler vessels: 1 x 20 L
CO2 Pump Flow Rates Range (LPM): 1.5 to 2 LPM
Max Operating Pressure (psi): 5000 psi, 344.74 bar
Maximum Process Temperature: 90°C
Skid Operating Temperature (C°): 5 to 40°C (15 to 30°C optimal)
CO2 Solvent Inlet Lines: 1
Eluent Inlet Lines: up to 2
User Interface: Touch Screen HMI panel with barcode scanner, maintenance tracking, recipe storage (parameter). 21 CFR Part 11 compliant software.
Biomass Loading and Unloading: 10 micron flexible no channel bags
Operating Humidity: 20 to 80%
Compliance - UL 508A electrical panel Electrical - 50 Hz 208V-240V, 3 phase,
Footprint:- 24ft. Dimensions - 99" x 34" x 72" (LxWxH)
Construction: 316 stainless steel, Ferrule compression fittingsthroughout
Sound Pressure - 50 dB
Wetted Materials - FDA approved structural stainless steel.
Chemical Compatibility: CO2, Organic Solvents, Acids and Bases, plant extracts
Flow Control: Manual, Automatic
Flowe Meter: PID Controlled Algorithm, rules based onprocess parameters
CE and food grade GMP certified
Independently P.E. Stamped according to ASME DIV II VII-2PED compliant, CE marked, notified body, Lloyd’s Register, CRN number available
Safety Specifications:
Rupture Discs: Zook burst discs, calibrated, ASME VIII Div IIcompliant, Max Pressure is 5300 psi, Certificate Attached to Disc
Temperature Switch: Preheater, Post heater MAX TEMP 140°C,Certificate Available Collector, Extractors MAX TEMP 100°C, Certificate Available
E-stop Switch: Switch disengages main contactor, not dependenton PLC
CO2 Gas Detector: Built in alarm, turns off pump and closes valves at9000
Interlocks: Marked with safety warnings
Pressure Transducers: Post pump, Extractor, Collector 1,3; Turns off pumpwhen overpressure (>5100 psi) condition is detected
Isolation Valves: Manual, bypass valves.
Technical documentation: available.

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Specifications

-------------------
Worked hours
Hours under power
State good
At local norms ---------
Status visible

About this seller

Client type Reseller
Active since 2023
Offers online 13
Last activity Dec. 24, 2024

Here is a selection of similar machines

USED SUPERCRITICAL CO2 EXTRACTOR Model: EXTRAKTLAB 140