Description
The Kalina plant was assembled and completed by 2016 as a facility to generate electricity and provide heat from geothermal energy. From 2016 to 2018, the commissioning of the power generation plant took place. After commissioning, the Kalina plant could only be operated at partial load. Later, technical problems arose, particularly with the turbine. Operation was discontinued and the geothermal wells were used to supply heat.
Composed of:
- Power Island :Evaporator - Kelvin
Year of manufacture: 2017
Quantity: 1 pc
Functional: Yes
Short description:
The evaporator is a hybrid heat exchanger, which is very compact in contrast to the usual tube bundle apparatus. The device also provides for the possibility of extracting heat at different temperature levels for district heating
- Power Island Generator - Atlas Copco
Year of manufacture: 2009
Quantity: 1 pc
Functional: Yes
Short description:
The 4-pole synchronous generator from Atlas Copco / WEG is part of the turbo set and is used to generate electricity. The generator is driven by the expansion turbine via the integral gearbox with coupling shaft. The rotational energy is converted into electric current. The generator has a connected load of 8,000 kVA, a heat transfer of approx. 28 MW . The dimensions of the generator are (LxWxH) 4.245 x 3.860 x 3.380 m and it has a weight of 30,000 kg. The generator is made of the material 1.4401 in plate construction.
The Bennig company has overhauled the generator.
- Power Island Integral gearbox - Atlas Copco
Quantity: 1 pc
Functional: Yes
Short description:
The Atlas Copco integral gearbox is driven by the expansion turbine and transmits the rotational movement to the generator via the coupling shaft.
In the gearbox, the turbine speed of max. 18,200 min-1 Grid feed-in speed of generator reduced from 1,500 min-1, approx. 4.5 MW maximum pressure. 45 bar, maximum pressure temperature. 160°C, inlet:350mm, outlet: 600mm, sound pressure level without sound insulation:92 dB(A), with sound insulation 85 dB(A). Variable inlet radial turbine, White metal bearings, Double mechanical seal, Seal medium: nitrogen
The integral gearbox is part of the turbine package.
- Power Island Capacitor - G.A.M. Heat
Year of manufacture: 2013
Quantity: 4 pcs.
Functional: Yes
Short description:
The condenser from G.A.M., Heat condenses and cools the liquid-vapour mixture coming from the LT recuperator. The condenser is designed for a permissible operating pressure of 16 bar and is constructed as a hybrid heat exchanger, which is very compact in contrast to the usual tube bundle apparatus. The condenser has a heat transfer capacity of 28 MW. The dimensions are (LxWxH)4.776x2.556x5.253 m and it has a weight of 32,300 kg when empty. The condenser is made of 265GH (1.0425, unalloyed steel).
- Power Island Storage tank - G.A.M. Heat
Year of manufacture: 2013
Quantity: 1 pcs.
Functional: Yes
Short description:
The G.A.M. Heat storage tank is the collection vessel for the ammonia water-vapour mixture.
It is designed for an operating overpressure of 16 bar. The tank is 13.43 m long and has a diameter of 1.5 m. The storage tank has a volume of 30,000 l and an empty weight of 9,514 kg.
- Power Island HP-Separator - Burges Manning
Year of manufacture: 2014
Quantity: 1 pcs.
Functional: Yes
Short description:
The HP (High Pressure) Separator from Burgess Manning is a pressure vessel and is located between the evaporator and turbine, The vessel is used to separate the vapour/liquid mixture from the evaporator. Its volume when empty is 5,000 I. The height is 5.05 m and the diameter 1.40 m. The HP-Separator is made of 1.4571 stainless austenitic steel.
- Power Island Coriolis measurements - Siemens Sitrans
Year of manufacture: 2015
Quantity: 2 pcs.
Functional: Yes
Short description:
The Siemens SITRANS FC410 Coriolis mass flowmeters are used to measure the flow of the ammonia-water mixture. The measurements are located upstream of the LT recuperator and downstream of the spray pump. Coriolis flowmeters measure the actual mass flow with a higher accuracy than comparable thermal mass flow measurements. The Coriolis measurement behind the LT recuperator is designed in DN 100 and for a pressure of 50.1 bar. The Coriolis measurement behind the spray pump is in DN 50 and designed for a pressure of 12.7 bar. The housing is made of stainless steel AlSI 304.
- Power Island Coriolis measurements - Siemens Sitrans
- Recooling plant Cooling water pumps- KSB
Year of manufacture: 2014
Quantity: 3
Functional: Yes
Short description:
The three cooling water pumps from KSB are horizontal, single-stage centrifugal pumps of the Etanorm RG 300 -360 series. They are designed for an operating pressure of 10 bar and a temperature of up to 140°C. The material of the cooling water pumps is grey cast iron JL 1040. The material of the cooling water pumps is grey cast iron JL 1040. The pumps are designed for a volume flow of 1,300 m=/h and a delivery head of 20 m.
Each pump comes with a Siemens electric motor.
- Recooling plant Hybrid cooling towers - Jaeggi Hydraulic Technology
Year of manufacture: 2014
Quantity: 7 pcs.
Functional: Yes
Short description:
The hybrid cooling towers of Jaeggi Hybridtechnologie are 3-flow cross/counterflow air coolers and serve to cool the cooling medium and to remove excess waste heat by means of ambient air (dry cooling). At higher ambient temperatures, the surface of the fin heat exchangers is additionally wetted with water to improve cooling. The cooled coolant is then returned to the cooling circuit. The cooling capacity is 3,000 kW / cooling water flow 276 m³/h.
The dimensions are (LxWxH) 12.788x3.076x4.901 m.
- Recooling plant Pressure maintenance system cooling water - Aqotec
Year of manufacture: 2015
Quantity: 3 pcs.
Functional: Yes
Short description:
The system pressure is kept constant in the cooling circuit by means of the pressure maintenance system. The expansion system consists of 3 buffer tanks that are pressurised with nitrogen and have an expansion volume of around 4.5 m3.
(3x1.5 m3). The buffer tanks are designed for an operating temperature of 75 C and an operating pressure of 0.5 bar. The tanks are 2.30 m high and have a diameter of 1.20 m.
If the pressure in the cooling water system drops, it is fed into the system by means of two CRIE5-5 pumps from Grundfos. In order to keep the pressure difference between the mains pressure and the feed pressure constant, the pumps are speed-controlled.
- Water treatment Bilfiger
More detailed information on request
Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase