Specifications

X-axis travel 90 mm
Y-axis travel 90 mm
Z-axis travel 30 mm
-------------------
Worked hours
Hours under power
State as-is, where-is
At local norms ---------
Status

Description

This KEYENCE IM-7020 optical measurement machine was manufactured in 2017. It offers precise and efficient inspection capabilities, ideal for quality control in various industries. Contact us for more information about this machine.

Image capture element: s/w-cmos, 1", 6. 6 megapixels
Display: lcd monitor, 10. 4", xga (1024×768)
Light collecting objective: double telecentric objectiveMeasurement Field
Wide Field Measurement Mode: 200 mm x 200 mm (4 x R50)
High Precision Measurement Mode: 125 mm x 125 mm
Display Resolution
Repeatability:
Wide Field Measurement Mode:
Without stage: ±1 µm
With stage: ±2 µm
High Precision Measurement Mode:
Without stage: ±0.5 µm
With stage: +1.5 µm
Measurement Accuracy
Wide Field Measurement Mode:
Normal Measurement: ±5 µm
Linked Measurement: ±(7 + 0.02L) µm²
High Precision Measurement Mode:
Normal Measurement: ±2 µm³
Linked Measurement: ±(4 + 0.02L) µm⁴
Light Sensor Measurement
Measurable Range (XY): 90 mm x 90 mm
Max. Measurement Depth: 30 mm
Diameter of Light Probe: 3 mm
Measurement Force: 0.015 N
Repeatability: +2 µm'5
Measurement Accuracy: ±(8 + 0.02L) µm
External Control Inputs and Outputs
External Remote Control Input: No voltage input (Contact/Solid State)
External Output OK/N.i.O./FAIL/MEASURE:
PhotoMOS Output
Rated Load: 24 VDC, 0.5 A
Maximum Switching Resistance: 50 mΩ
Interfaces
LAN: RJ-45 (10BASE-T/100BASE-TX/1000BASE-T)
USB 2.0 Ports: 6 connectors (front: 2, rear: 4)
Storage
Hard Drive: 500 GB
Environmental Conditions
Ambient Temperature: +10 to 35° C
Relative Humidity: 20 to 80% (no condensation)
Pollution Degree: 2
Overvoltage Category: II
Lighting System
Through-light: Telecentric through-light
Incident Light: Four-part lighting from marked angles (electrically), slit ring lighting
Object Table
XY Object Table:
Movement Range: 100 mm x 100 mm (electrical)
Max. Load Capacity: 5 kg
Z Object Table:
Movement Range: 75 mm (electrical)
Power Supply
Supply Voltage: 100 to 240 AC, 50/60 Hz
Power Consumption: Max. 430 VA
Weight (kg)
Controller: Approx. 8 kg
Measurement Head: Approx. 31 kg

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Client type Reseller
Active since 2019
Offers online 1010
Last activity Jan. 30, 2025

Description

This KEYENCE IM-7020 optical measurement machine was manufactured in 2017. It offers precise and efficient inspection capabilities, ideal for quality control in various industries. Contact us for more information about this machine.

Image capture element: s/w-cmos, 1", 6. 6 megapixels
Display: lcd monitor, 10. 4", xga (1024×768)
Light collecting objective: double telecentric objectiveMeasurement Field
Wide Field Measurement Mode: 200 mm x 200 mm (4 x R50)
High Precision Measurement Mode: 125 mm x 125 mm
Display Resolution
Repeatability:
Wide Field Measurement Mode:
Without stage: ±1 µm
With stage: ±2 µm
High Precision Measurement Mode:
Without stage: ±0.5 µm
With stage: +1.5 µm
Measurement Accuracy
Wide Field Measurement Mode:
Normal Measurement: ±5 µm
Linked Measurement: ±(7 + 0.02L) µm²
High Precision Measurement Mode:
Normal Measurement: ±2 µm³
Linked Measurement: ±(4 + 0.02L) µm⁴
Light Sensor Measurement
Measurable Range (XY): 90 mm x 90 mm
Max. Measurement Depth: 30 mm
Diameter of Light Probe: 3 mm
Measurement Force: 0.015 N
Repeatability: +2 µm'5
Measurement Accuracy: ±(8 + 0.02L) µm
External Control Inputs and Outputs
External Remote Control Input: No voltage input (Contact/Solid State)
External Output OK/N.i.O./FAIL/MEASURE:
PhotoMOS Output
Rated Load: 24 VDC, 0.5 A
Maximum Switching Resistance: 50 mΩ
Interfaces
LAN: RJ-45 (10BASE-T/100BASE-TX/1000BASE-T)
USB 2.0 Ports: 6 connectors (front: 2, rear: 4)
Storage
Hard Drive: 500 GB
Environmental Conditions
Ambient Temperature: +10 to 35° C
Relative Humidity: 20 to 80% (no condensation)
Pollution Degree: 2
Overvoltage Category: II
Lighting System
Through-light: Telecentric through-light
Incident Light: Four-part lighting from marked angles (electrically), slit ring lighting
Object Table
XY Object Table:
Movement Range: 100 mm x 100 mm (electrical)
Max. Load Capacity: 5 kg
Z Object Table:
Movement Range: 75 mm (electrical)
Power Supply
Supply Voltage: 100 to 240 AC, 50/60 Hz
Power Consumption: Max. 430 VA
Weight (kg)
Controller: Approx. 8 kg
Measurement Head: Approx. 31 kg

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Specifications

X-axis travel 90 mm
Y-axis travel 90 mm
Z-axis travel 30 mm
-------------------
Worked hours
Hours under power
State as-is, where-is
At local norms ---------
Status

About this seller

Client type Reseller
Active since 2019
Offers online 1010
Last activity Jan. 30, 2025