Specifications

-------------------
Worked hours
Hours under power
State good
At local norms ---------
Status visible

Description

Quattro Peak L Plus in excellent condition

Specifications:
Overall dimensions
Length (with 3-stage cooling zone): 5.) 6714 mm
Width: 1435 mm
Height (in delivery condition / incl. warning light): 2.) 1647 mm / 2233 mm
Inlet height, adjustable by customer: 2.) 830 ... 1030 ±20 mm
Weight approx. 2800 kg
Number / diameter foot: 14 / 80 mm
Max. floor loading: 750 kg/m²
Process area
Length: 6392.5 mm
Pre-heating zones: 5
Peak zone (top/bottom): 3 peak zones with 6 heating modules (3 top/3 bottom)
Bottom heating modules pre-heating zones (option): 5
Heated tunnel length, total: 4167 mm
Active convection length: Length of cooling zone 1- / 2- / 3- / 4- / 5-stage: 1278.5 / 1752 / 2225.5 / 2822.5 / 3296 mm
Temperature measurement: NiCr-Ni sensors in the hot gas flow
Warm-up time: approx. 30 min.
Heat transfer: 100% forced convection
Process temperature (pre-heating zone/peak zone): max. 300 °C (pre-heating zone) / 350 °C (Peak)
Transport chain conveyor
Working width usable with PCB support: 60 ... 510 mm
Usable working width with PCB support: PIN level ... -10 mm
Pass through height (top/bottom): 30/30 mm
Max. loading: 3 kg/m
Transport mesh belt conveyor
Usable working width: 500 mm
Pass through height (top): 30 mm
Max. loading: 3 kg/m
Conveyor speed 0.2 ... 3.0 m/min
Average conveyor speed 0.7 ... 1.2 m/min.
Exhaustion 3.)
Suction pipe: 1 x Ø 200 mm
Required exhaust air at pipe (inlet): approx. 600 … 800 m3/h
Temperature of exhaust air at the pipe: < 50 °C
Internal exhaust air resistance of oven: 3 - 8 mbar
Continuous sound pressure level < 70 dB(A)
Control Unit CDIAS with RT 7
Nitrogen supply * 4.)
Connecting armature (clamped joint for Cu-pipe): R 3/8“ internal thread
Working pressure (at connecting armature): 6 ... 8 bar approx. 9 m3
N2-consumption, steady state condition and transport width 220 mm: 6.) approx. 9 m3/h
N2-consumption, full load and transport width 220 mm: 7.) approx. 15 m3/h
Readiness for the system (1000 ppm, N2 < 5 ppm O2): approx. 15 min.
Power supply
Connecting power supply: 3~N, PE 230 / 400 V, 50 Hz
Max. current consumption per phase: 95A
Power consumption during heat-up: 64 kW
Power consumption steady state condition: 1.) approx. 9 kW h

For further information please do not hesistate to contact us.

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Client type Reseller
Active since 2019
Offers online 49
Last activity Oct. 3, 2024

Description

Quattro Peak L Plus in excellent condition

Specifications:
Overall dimensions
Length (with 3-stage cooling zone): 5.) 6714 mm
Width: 1435 mm
Height (in delivery condition / incl. warning light): 2.) 1647 mm / 2233 mm
Inlet height, adjustable by customer: 2.) 830 ... 1030 ±20 mm
Weight approx. 2800 kg
Number / diameter foot: 14 / 80 mm
Max. floor loading: 750 kg/m²
Process area
Length: 6392.5 mm
Pre-heating zones: 5
Peak zone (top/bottom): 3 peak zones with 6 heating modules (3 top/3 bottom)
Bottom heating modules pre-heating zones (option): 5
Heated tunnel length, total: 4167 mm
Active convection length: Length of cooling zone 1- / 2- / 3- / 4- / 5-stage: 1278.5 / 1752 / 2225.5 / 2822.5 / 3296 mm
Temperature measurement: NiCr-Ni sensors in the hot gas flow
Warm-up time: approx. 30 min.
Heat transfer: 100% forced convection
Process temperature (pre-heating zone/peak zone): max. 300 °C (pre-heating zone) / 350 °C (Peak)
Transport chain conveyor
Working width usable with PCB support: 60 ... 510 mm
Usable working width with PCB support: PIN level ... -10 mm
Pass through height (top/bottom): 30/30 mm
Max. loading: 3 kg/m
Transport mesh belt conveyor
Usable working width: 500 mm
Pass through height (top): 30 mm
Max. loading: 3 kg/m
Conveyor speed 0.2 ... 3.0 m/min
Average conveyor speed 0.7 ... 1.2 m/min.
Exhaustion 3.)
Suction pipe: 1 x Ø 200 mm
Required exhaust air at pipe (inlet): approx. 600 … 800 m3/h
Temperature of exhaust air at the pipe: < 50 °C
Internal exhaust air resistance of oven: 3 - 8 mbar
Continuous sound pressure level < 70 dB(A)
Control Unit CDIAS with RT 7
Nitrogen supply * 4.)
Connecting armature (clamped joint for Cu-pipe): R 3/8“ internal thread
Working pressure (at connecting armature): 6 ... 8 bar approx. 9 m3
N2-consumption, steady state condition and transport width 220 mm: 6.) approx. 9 m3/h
N2-consumption, full load and transport width 220 mm: 7.) approx. 15 m3/h
Readiness for the system (1000 ppm, N2 < 5 ppm O2): approx. 15 min.
Power supply
Connecting power supply: 3~N, PE 230 / 400 V, 50 Hz
Max. current consumption per phase: 95A
Power consumption during heat-up: 64 kW
Power consumption steady state condition: 1.) approx. 9 kW h

For further information please do not hesistate to contact us.

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Specifications

-------------------
Worked hours
Hours under power
State good
At local norms ---------
Status visible

About this seller

Client type Reseller
Active since 2019
Offers online 49
Last activity Oct. 3, 2024

Here is a selection of similar machines

Quattro Peak L Plus PCB Reflow oven