Specifications

-------------------
Length x width x height 1890.0 × 1370.0 × 2420.0
Weight 400 kg
Worked hours
Hours under power
State good
At local norms ---------
Status visible

Description

DESCRIPTION:
Vertical laminar flow and microbiological safety (biohazard) cabin mainly used for cytostatics. The safety cabins are defined as Class II as they are equipped with a partial frontal working opening capable of allowing the extraction of 30% of the air and a recirculation system for the remaining 70%. which is sent to the work area in laminar flow.

SECTORS OF USE:
Pharmaceutical, chemical, cosmetics, food, dietary, medical devices, manufacturing.

MAIN FEATURES:
Vertical laminar flow hoods are designed to ensure the protection of products, the operator and the surrounding environment. Furthermore, they are mostly suitable for the preparation and manipulation of: cytotoxic drugs, antineoplastic chemotherapeutics, CMR drugs and any other agent that can cause genetic alterations or synergistic activities with other materials. The air that is sucked in from the front passes under the work surface and next to the side walls of the internal chamber, not entering the work area thanks to the vertical laminar flow which simultaneously descends throughout the internal chamber, and which it joins under the work surface. The air sucked in by the main motorized fan is directed into a plenum where approximately 70% is sent back into the work area through absolute filtration while the remaining 30% is expelled outside with the aid of a second motorized fan, following a second filtration absolute (air recirculation system). Furthermore, the quantity of expelled air is replenished with an equal quantity of ambient air sucked in through the front working opening, generating an isolating "front barrier" to protect the operator. The vertical laminar air flow and the expulsion air flow are filtered by filters.

Year: 2002

TECHNICAL DATA
Power supply 230 V – 23 A – 50 Hz
Dimensions (LxWxH) 1890 x 1370 x 2420 mm
Weight 400 kg

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Client type Reseller
Active since 2009
Offers online 1085
Last activity Nov. 22, 2024

Description

DESCRIPTION:
Vertical laminar flow and microbiological safety (biohazard) cabin mainly used for cytostatics. The safety cabins are defined as Class II as they are equipped with a partial frontal working opening capable of allowing the extraction of 30% of the air and a recirculation system for the remaining 70%. which is sent to the work area in laminar flow.

SECTORS OF USE:
Pharmaceutical, chemical, cosmetics, food, dietary, medical devices, manufacturing.

MAIN FEATURES:
Vertical laminar flow hoods are designed to ensure the protection of products, the operator and the surrounding environment. Furthermore, they are mostly suitable for the preparation and manipulation of: cytotoxic drugs, antineoplastic chemotherapeutics, CMR drugs and any other agent that can cause genetic alterations or synergistic activities with other materials. The air that is sucked in from the front passes under the work surface and next to the side walls of the internal chamber, not entering the work area thanks to the vertical laminar flow which simultaneously descends throughout the internal chamber, and which it joins under the work surface. The air sucked in by the main motorized fan is directed into a plenum where approximately 70% is sent back into the work area through absolute filtration while the remaining 30% is expelled outside with the aid of a second motorized fan, following a second filtration absolute (air recirculation system). Furthermore, the quantity of expelled air is replenished with an equal quantity of ambient air sucked in through the front working opening, generating an isolating "front barrier" to protect the operator. The vertical laminar air flow and the expulsion air flow are filtered by filters.

Year: 2002

TECHNICAL DATA
Power supply 230 V – 23 A – 50 Hz
Dimensions (LxWxH) 1890 x 1370 x 2420 mm
Weight 400 kg

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Specifications

-------------------
Length x width x height 1890.0 × 1370.0 × 2420.0
Weight 400 kg
Worked hours
Hours under power
State good
At local norms ---------
Status visible

About this seller

Client type Reseller
Active since 2009
Offers online 1085
Last activity Nov. 22, 2024

Here is a selection of similar machines

STERIL MOD. DISPENSING - Biosafety cabinet used