Specifications

-------------------
Worked hours
Hours under power
State good
At local norms ---------
Status

Description

Varian 9050 Variable Wavelength UV-VIS Detector
The Varian 9050 detector has the following general specifications (FROM MANUFACTURERS LITERATURE): Diagnostics: Built-in Self-Test and diagnostics. Time Programming: Time-programmable wavelength, recorder attenuation, autozero, time constant, peaksense, timeslice, pulse, and external event relays. Time constant is programmable at time zero only. Store up to five methods with memory power interrupt protection. Wavelength: Deuterium lamp and automatically controlled second order filter, 190-700 nm. Flow Cell: 15 0 volume, 8 mm pathlength. Pressure: 2000 psi maximum on all flow cells. Time Constant: 0.05, 0.5, 1.0, and 5.0 sec. selectable from the keyboard. Spectral Bandwidth: 5 nm. Recorder Output: Selectable Absorbance Ranges-0.001, 0.002, 0.005, 0.01, 0.02, 0.05, 0. 1, 0.2, 0.5, 1.0, and 2.0 AU=1 mV or 10 mV (switch selectable). Data System Output: 2 AU 1 volt or 10 volts, selectable from the rear panel. Peak Sensing: Peak Start Peak End, Valley, Timeslice, and Pulse will activate the Peaksense relay and generate event marks on the recorder chart.

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Client type Reseller
Active since 2011
Offers online 140
Last activity Nov. 4, 2024

Description

Varian 9050 Variable Wavelength UV-VIS Detector
The Varian 9050 detector has the following general specifications (FROM MANUFACTURERS LITERATURE): Diagnostics: Built-in Self-Test and diagnostics. Time Programming: Time-programmable wavelength, recorder attenuation, autozero, time constant, peaksense, timeslice, pulse, and external event relays. Time constant is programmable at time zero only. Store up to five methods with memory power interrupt protection. Wavelength: Deuterium lamp and automatically controlled second order filter, 190-700 nm. Flow Cell: 15 0 volume, 8 mm pathlength. Pressure: 2000 psi maximum on all flow cells. Time Constant: 0.05, 0.5, 1.0, and 5.0 sec. selectable from the keyboard. Spectral Bandwidth: 5 nm. Recorder Output: Selectable Absorbance Ranges-0.001, 0.002, 0.005, 0.01, 0.02, 0.05, 0. 1, 0.2, 0.5, 1.0, and 2.0 AU=1 mV or 10 mV (switch selectable). Data System Output: 2 AU 1 volt or 10 volts, selectable from the rear panel. Peak Sensing: Peak Start Peak End, Valley, Timeslice, and Pulse will activate the Peaksense relay and generate event marks on the recorder chart.

Please note that this description may have been translated automatically. Contact us for further information. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase


Specifications

-------------------
Worked hours
Hours under power
State good
At local norms ---------
Status

About this seller

Client type Reseller
Active since 2011
Offers online 140
Last activity Nov. 4, 2024

Here is a selection of similar machines

Varian 9050 Variable Wavelength UV-VIS Detector